Older boiler diagnosis
We identify the model, check the manual and assess what can be repaired.
Ask about your boilerWe identify the model, check the manual and look into parts before recommending the next step.
The phone is answered 24 hours a day, by a person and not a machine.
A fault code narrows down where to look. It does not say whether a boiler is worth repairing, and it does not say which part has failed. Below is what the manufacturer manual says, with the page it says it on.
Your boiler
Or tap one we have:
Pick your boiler, then type the code on its display. The manual’s answer appears here.
| Model and fault | What it can mean | Manual source | What to do first |
|---|---|---|---|
Baxi Bermuda BBU 15 HEE133
|
Interruption of the gas supply, failed ignition, or no flame detected. On this model a three digit code is shown split, so E133 appears as "E1" alternating with "33". |
Installation & Servicing Instructions, 2014, p. 36 [M] | Inspect first. Often the gas supply or the ignition, not the boiler. |
Baxi Bermuda BBU 15 HEE158
|
Condensate discharge system fault. | Installation & Servicing Instructions, 2014, p. 36 [M] | Assess the drain before anything else. A frozen or blocked pipe is common. |
Baxi Bermuda BBU 15 HEE125
|
Circulation fault in the primary circuit. The manual gives the trigger as the boiler exceeding the selected temperature by 25°C twice within two hours of the burner lighting. | Installation & Servicing Instructions, 2014, p. 36 [M] | Check circulation and the water in the system first. |
Baxi Bermuda BBU 15 HEE110
|
The primary water has overheated, or there is excess condensate in the sump. The manual limits the boiler to four resets in any five hour period. |
Installation & Servicing Instructions, 2014, p. 36 [M] | Assess the cause. The manual allows a reset, held for five seconds. |
Potterton Promax Store 24E110
|
Safety thermostat operated: the primary water has overheated. | Installation and Service Manual, p. 47 [M] | Check the radiator valves are open. Repeated overheating is not something to keep resetting. |
Potterton Promax Store 24E119
|
Water pressure switch not operated: the primary water pressure is below 0.5 bar. | Installation and Service Manual, p. 47 [M] | Read the pressure gauge and look for a visible leak. If it keeps dropping after a refill, there is a leak. |
Potterton Promax Store 24E125
|
Pump fault or a primary circulation problem. The manual says the pump is probably not working. | Installation and Service Manual, p. 47 [M] | Check the radiator valves are open. If the code stays, the pump needs an engineer. |
Potterton Promax Store 24E130
|
Flue sensor operated: the flue system has overheated. | Installation and Service Manual, p. 47 [M] | Do not reset it. Turn the boiler off and have it checked before it is used again. |
Potterton Promax Store 24E133
|
Interruption of the gas supply, failed ignition, or no flame detected. | Installation and Service Manual, p. 47 [M] | Check other gas appliances work and the meter is on and in credit. In cold weather, check the outside condensate pipe has not frozen. |
Potterton Promax Store 24E160
|
Fan or fan wiring fault. | Installation and Service Manual, p. 47 [M] | Do not keep resetting it. The fan clears the combustion gases, so this is safety critical. |
Potterton Promax Store 24E193
|
Pre-circulation fault. | Installation and Service Manual, p. 47 [M] | Have it looked at by an engineer. |
Meanings come from the manufacturer manual. Repair guidance depends on inspection and on parts.
A code on its own cannot decide whether a boiler should be replaced.
A discontinued boiler deserves a proper assessment.
We identify the model, check the manual and assess what can be repaired.
Ask about your boilerWe look at parts, condition and how long the model can be supported before recommending the next step.
Ask about your boilerWe find the fault, explain it, and fix it where the part can be had.
Ask about your boilerAn annual check keeps small faults from turning into breakdowns.
Ask about your boilerRepairs to unvented hot water cylinders and their controls.
Ask about your boilerA model number or a photograph is a useful first step.
We ask a few questions and note the model if you have it.
We look up the manual and find out what can be had.
We explain the options and only go ahead with your approval.
A price for a boiler nobody has seen is a guess. We look at yours first.
Tell us where you are and what the boiler is doing. We will call you back.
Often, yes. We identify the model from the data badge and check what stockists hold before anything is agreed. Where a part is no longer held, we will tell you.
Yes. There is no law against an older boiler. It has to be safe, and a Gas Safe registered engineer has to say so.
Many firms only work on models they fit themselves. We work on older and discontinued ranges, which is the whole point of this business.
A price for a boiler nobody has seen is a guess. We look at yours, then give you a clear quote before any work begins.